Physics
Scientific paper
Feb 1976
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1976stin...7712322h&link_type=abstract
Unknown
Physics
Direct Current, Limiter Circuits, Mines (Excavations), Power Lines, Current Regulators, Electric Power Transmission, Mercury (Metal), Power Supply Circuits, Switching Circuits
Scientific paper
Feasibility is determined for using current limiting devices (CLD) in switching heavy DC currents (1,200 and 600 amperes) at utilization voltages used in the mining industry (300 and 600 volts, nominal). Use of a CLD in this application is based on its orders of magnitude change in resistance when it changes state (from liquid mercury to vapor) after being subjected to short time, high density current. Switching times on the order of 3 to 4 milliseconds have been obtained.
Hamilton H. B.
Ramos T. J.
No associations
LandOfFree
Feasibility study of the use of current limiting devices in interruption and sectionalizing of DC circuits in mines does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Feasibility study of the use of current limiting devices in interruption and sectionalizing of DC circuits in mines, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Feasibility study of the use of current limiting devices in interruption and sectionalizing of DC circuits in mines will most certainly appreciate the feedback.