Fast Neutron Detector for Fusion Reactor KSTAR Using Stilbene Scintillator

Physics – Nuclear Physics – Nuclear Experiment

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

15 pages, 14 figures, conference

Scientific paper

Various neutron diagnostic tools are used in fusion reactors to evaluate different aspects of plasma performance, such as fusion power, power density, ion temperature, fast ion energy, and their spatial distributions. The stilbene scintillator has been proposed for use as a neutron diagnostic system to measure the characteristics of neutrons from the Korea Superconducting Tokamak Advanced Research (KSTAR) fusion reactor. Specially designed electronics are necessary to measure fast neutron spectra with high radiation from a gamma-ray background. The signals from neutrons and gamma-rays are discriminated by the digital charge pulse shape discrimination (PSD) method, which uses total to partial charge ratio analysis. The signals are digitized by a flash analog-to-digital convertor (FADC). To evaluate the performance of the fabricated stilbene neutron diagnostic system, the efficiency of 10 mm soft-iron magnetic shielding and the detection efficiency of fast neutrons were tested experimentally using a 252Cf neutron source. In the results, the designed and fabricated stilbene neutron diagnostic system performed well in discriminating neutrons from gamma-rays under the high magnetic field conditions during KSTAR operation. Fast neutrons of 2.45 MeV were effectively measured and evaluated during the 2011 KSTAR campaign.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Fast Neutron Detector for Fusion Reactor KSTAR Using Stilbene Scintillator does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Fast Neutron Detector for Fusion Reactor KSTAR Using Stilbene Scintillator, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Fast Neutron Detector for Fusion Reactor KSTAR Using Stilbene Scintillator will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-37264

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.