Extensive Penetrating Cosmic Ray Showers

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

6

Scientific paper

Extensive penetrating cosmic-ray showers were recorded with an arrangement consisting of a penetrating shower set P and an extension E containing shielded and unshielded counters. The following results were obtained: (1) The effective density integral spectrum of the showers observed is given by D(x) = Ax-0\cdot 5, where x is the number of particles per m.2. (2) The rate of shower coincidences decreases only slightly when the extension is moved from a distance of 0\cdot 5 m. to a distance of 9 m. from the main set P. (3) The ratio of the coincidences obtained with shielded and unshielded extension counters does not change noticeably with increasing separation between E and P. The results are based on approximately 10,000 hr. of recording.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Extensive Penetrating Cosmic Ray Showers does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Extensive Penetrating Cosmic Ray Showers, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Extensive Penetrating Cosmic Ray Showers will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1432654