Scientific paper
We present a detailed experimental study of the Uhrig Dynamical Decoupling (UDD) sequence in a variety of noise environments. Our qubit system consists of a crystalline array of $^{9}$Be$^{+}$ ions confined in a Penning trap. We use an electron-spin-flip transition as our qubit manifold and drive qubit rotations using a 124 GHz microwave system. We study the effect of the UDD sequence in mitigating phase errors and compare against the well known CPMG-style multipulse spin echo as a function of pulse number, rotation axis, noise spectrum, and noise strength. Our results agree well with theoretical predictions for qubit decoherence in the presence of classical phase noise, accounting for the effect of finite-duration $\pi$ pulses. Finally, we demonstrate that the Uhrig sequence is more robust against systematic over/underrotation and detuning errors than is multipulse spin echo, despite the precise prescription for pulse-timing in UDD.
Biercuk Michael J.
Bollinger John. J.
Itano Wayne M.
Shiga Nobuyasu
Uys Hermann
No associations
LandOfFree
Experimental Uhrig Dynamical Decoupling using Trapped Ions does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Experimental Uhrig Dynamical Decoupling using Trapped Ions, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Experimental Uhrig Dynamical Decoupling using Trapped Ions will most certainly appreciate the feedback.