Estimates of in-flight calibration source activities for the SIXS X-ray detectors on board BepiColombo

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The Solar Intensity X-ray and particle Spectrometer (SIXS) instrument on the BepiColombo Mercury Planetary Orbiter consists of three X-ray detectors and a particle detector system. The X-ray detectors must be calibrated repeatedly during the BepiColombo mission due to the variable conditions in orbit around Mercury by measuring the spectrum of a known calibration source between observations. The calibration sources of the SIXS X-ray detectors are placed inside each detector assembly. The placement, design and activity of the calibration sources must be carefully optimized since the sources are within the field of view at all times. The primary motive for the present study was to find the best design alternative for the on board calibration sources of the SIXS X-ray detectors.The calibration sources of the SIXS detectors consist of titanium coated 55Fe. Two different options for the source placement were considered and Ruby′s formula for a parallel-disk source and detector system was used, in addition to the analytical examination of the attenuation and fluorescence of X-rays inside the Ti-coating, to estimate the calibration signal for each option. Given the complexity of the source-detector geometry, approximations were required for the analytical estimations of the attenuation and fluorescence. Two different approximations were applied to each source-detector configuration. Monte-Carlo simulation program was also developed to estimate the SIXS calibration signal more accurately as well as to provide means to estimate the signal in more general source-detector systems. The Monte-Carlo simulation results of each source-detector configuration were consistent with the results of the analytical calculations. The optimal activity, dimensions and placement of the SIXS calibration sources as well as the optimal thickness of the Ti-coating were determined from the simulation results in co-operation with Oxford Instruments Analytical Ltd. On the basis of the results, the design with the radiation source above the aperture stop was adopted for the SIXS X-ray detectors.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Estimates of in-flight calibration source activities for the SIXS X-ray detectors on board BepiColombo does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Estimates of in-flight calibration source activities for the SIXS X-ray detectors on board BepiColombo, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Estimates of in-flight calibration source activities for the SIXS X-ray detectors on board BepiColombo will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-767484

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.