Effects of bone- and air-tissue inhomogeneities on the dose distributions of the Leksell Gamma Knife$^{\circledR}$ calculated with PENELOPE

Physics – Medical Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

13 pages, 8 figures, 2 tables

Scientific paper

10.1088/0031-9155/50/23/018

Monte Carlo simulation with PENELOPE (v.~2003) is applied to calculate Leksell Gamma Knife$^{\circledR}$ dose distributions for heterogeneous phantoms. The usual spherical water phantom is modified with a spherical bone shell simulating the skull and an air-filled cube simulating the frontal or maxillary sinuses. Different simulations of the 201 source configuration of the Gamma Knife have been carried out with a simplified model of the geometry of the source channel of the Gamma Knife recently tested for both single source and multisource configurations. The dose distributions determined for heterogeneous phantoms including the bone- and/or air-tissue interfaces show non negligible differences with respect to those calculated for a homogeneous one, mainly when the Gamma Knife isocenter approaches the separation surfaces. Our findings confirm an important underdosage ($\sim$10%) nearby the air-tissue interface, in accordance with previous results obtained with PENELOPE code with a procedure different to ours. On the other hand, the presence of the spherical shell simulating the skull produces a few percent underdosage at the isocenter wherever it is situated.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Effects of bone- and air-tissue inhomogeneities on the dose distributions of the Leksell Gamma Knife$^{\circledR}$ calculated with PENELOPE does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Effects of bone- and air-tissue inhomogeneities on the dose distributions of the Leksell Gamma Knife$^{\circledR}$ calculated with PENELOPE, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Effects of bone- and air-tissue inhomogeneities on the dose distributions of the Leksell Gamma Knife$^{\circledR}$ calculated with PENELOPE will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-242162

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.