Nucl.Instrum.Meth. A511 (2003) 408-416
Physics
High Energy Physics
High Energy Physics - Experiment
19 pages, 1 table, 10 figures
Scientific paper
10.1016/S0168-9002(03)02020-5
Flash Analog to Digital Convertor (FADC) is frequently used in nuclear and particle physics experiments, often as the major component in big multi-channel systems. The large data volume makes the optimization of operating parameters necessary. This article reports a study of a method to extend the dynamic range of an 8-bit FADC from the nominal $\rm{2^8}$ value. By comparing the integrated pulse area with that of a reference profile, good energy reconstruction and event identification can be achieved on saturated events from CsI(Tl) crystal scintillators. The effective dynamic range can be extended by at least 4 more bits. The algorithm is generic and is expected to be applicable to other detector systems with FADC readout.
No associations
LandOfFree
Effective Dynamic Range in Measurements with Flash Analog-to-Digital Convertor does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Effective Dynamic Range in Measurements with Flash Analog-to-Digital Convertor, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Effective Dynamic Range in Measurements with Flash Analog-to-Digital Convertor will most certainly appreciate the feedback.