Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron TILE Calorimeter

Physics – High Energy Physics – High Energy Physics - Experiment

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

24 pages, 13 figures

Scientific paper

The hadronic shower longitudinal and lateral leakages and its effect on the pion response and energy resolution of iron-scintillator barrel hadron prototype calorimeter with longitudinal tile configuration with a thickness of 9.4 nuclear interaction lengths have been investigated. The results are based on 100 GeV pion beam data at incidence angle $\Theta = 10^o$ at impact point Z in the range from - 36 to 20 cm which were obtained during test beam period in May 1995 with setup equipped scintillator detector planes placed behind and back of the calorimeter. The fraction of the energy of 100 GeV pions at $\Theta = 10^o$ leaking out at the back of this calorimeter amounts to 1.8 % and agrees with the one for a conventional iron-scintillator calorimeter. Unexpected behaviour of the energy resolution as a function of leakage is observed: 6 % lateral leakage lead to 18 % improving of energy resolution in compare with the showers without leakage. The measured values of longitudinal punchthrough probability $(18 \pm 1) %$ and $(20 \pm 1) %$ for two different hit definitions of leaking events agree with the earlier measurement for our calorimeter and with the one for a conventional iron-scintillator calorimeter with the same nuclear interaction length thickness respectively. Due to more soft cut for hit definition in the leakage detectors the measured value of longitudinal punchthrough probability more corresponds to the calculated iron equivalent length $L_{Fe} = 158 cm$.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron TILE Calorimeter does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron TILE Calorimeter, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron TILE Calorimeter will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-41788

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.