Physics – Optics
Scientific paper
May 2001
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2001aas...198.0506t&link_type=abstract
American Astronomical Society, 198th AAS Meeting, #05.06; Bulletin of the American Astronomical Society, Vol. 33, p.791
Physics
Optics
Scientific paper
We present new science results from TNTCAM2 obtained at the WIRO 2.3 meter telescope. These include: (1) polarization maps of the BN object and a section of M42 around the Trapezium that shows bow shocks; (2) imaging and polarimetry of selected circumstellar shells of evolved stars and planetary nebulae; (3) new mid-IR photometry of ISO selected Vega-type stars showing a mid-infrared spectral energy excess, and (4) attempts to detect proplyds in Orion. The photometry and polarimetry of bright sources allows us to characterize the system performance in terms of throughput of the optics and net system sensitivity, which we compare to the sensitivity of TNTCAM1 at WIRO (S/N = 5 on an 8.0 magnitude 11.5μ m source (20 mJy) over a 30 minutes of coadded .03s integrations). We also present the efficiency of the polarization analyzer and a comparison of our polarization measurments of selected bright objects with previous measurements in the mid-IR. We discuss and demonstrate the remote use of TNTCAM2 on the Wyoming Infra-Red Observatory (WIRO) telescope. The remote observer can connect to the observatory computers from a variety of operating systems using AT&T's Virtual Network Computing software. Remote real-time control of the telescope and TNTCAM2 have already been achieved from the University of Denver over a standard ethernet connection through WIRO's 10.5 Mbps microwave link. We thank Craig Smith for invaluable suggestions and guidance in collecting and reducing polarimetry data in the mid-IR. We acknowledge support under NSF grant AST-9724506 to the University of Denver and NASA EPSCoR grant #NCC5-414 to the University of Wyoming.
Cash Jennifer Lynn
Edwards M. E.
Johnson Paul E.
Jurgenson Colby A.
Klebe Dimitri I.
No associations
LandOfFree
Early Results from TNTCAM2, a Mid-IR Imaging Polarimeter, and Remote Internet Observing does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Early Results from TNTCAM2, a Mid-IR Imaging Polarimeter, and Remote Internet Observing, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Early Results from TNTCAM2, a Mid-IR Imaging Polarimeter, and Remote Internet Observing will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1267506