Dosimetric equivalence of non-standard high dose rate (HDR) brachytherapy catheter patterns

Physics – Medical Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

12 pages, 5 figures

Scientific paper

Purpose: To determine whether alternative HDR prostate brachytherapy catheter patterns can result in improved dose distributions while providing better access and reducing trauma. Methods: Prostate HDR brachytherapy uses a grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. On CT data from ten previously-treated patients new catheters were digitized following three catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage. Results: Thirty plans from ten patients were optimized. All non-standard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Dosimetric equivalence of non-standard high dose rate (HDR) brachytherapy catheter patterns does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Dosimetric equivalence of non-standard high dose rate (HDR) brachytherapy catheter patterns, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Dosimetric equivalence of non-standard high dose rate (HDR) brachytherapy catheter patterns will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-592407

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.