Disposable cuvette test for enzymatic determination of heavy metals

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

We report on an optical cuvette test for total heavy metals based on the inhibition of the enzyme urease by metals ions including silver(I), mercury(II), copper(II), nickel(II), cobalt(II), and cadmium(II). The enzymatic action is monitored using an optical ammonia transducer deposited on the wall of a disposable cuvette. This results in a rapid and inexpensive single-shot device for heavy metal sensing. A solution of urease and buffer is placed in the cuvette with the ammonium sensor membrane fixed on one of its walls. Enzymatic action starts after addition of a defined quantity of urea. This is indicated by the increase in the absorption of the ammonia sensor membrane whose color changes from yellow to blue. The slop of the increase in signal is the information for the un-inhibited reaction. After several minutes,the sample (containing the heavy metal) is added to the cuvette. Heavy metal ions inhibit the enzyme (by binding to the sulfhydryl groups) and cause a decrease in the slope. The ratio of slopes of un-inhibited and inhibited reactions is a direct parameter for detecting and calculating total heavy metals. The optimum pH was a trade-off between optimum enzyme activity (pH 7 at 25 degree(s)C) and the relative signal change of the ammonia-sensor (highest at pH 8). pH 7.5 was found to be optimal. The system was calibrated at optimized activities of urease (1.5 (mu) ) and an optimized urea concentration (0.5 mmol). Heavy metals inhibit in the following order: Ag(I) > Hg(II) > Cu(II) >> Ni(II) > Co(II) > Cd(II) > Fe(III) > Pb(II), Zn(II). The following concentrations that cause 50% inhibition were found: Ag(I) (0.1 ppm), Hg(II) (0.5 ppm), Cu(II) (0.5 ppm), Ni(II) (7 ppm), Co(II) (30 ppm), Cd(II) (95 ppm), Fe(III) (50 ppm), Zn(II) (85 ppm) and Pb(II) (210 ppm). We also studied the inhibitory effect of combinations of metal ions, the influence of ionic strength, and the effect of incubation time.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Disposable cuvette test for enzymatic determination of heavy metals does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Disposable cuvette test for enzymatic determination of heavy metals, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Disposable cuvette test for enzymatic determination of heavy metals will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1357046

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.