10.1088/1367-2630/10/10/103017
The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved background suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubbles on alpha tracks, compared to single nucleations created by neutron induced recoils.
Aubin Françcois
Auger Martin
Behnke E.
Beltran B.
Clark Kate
No associations
LandOfFree
Discrimination of nuclear recoils from alpha particles with superheated liquids does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Discrimination of nuclear recoils from alpha particles with superheated liquids, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Discrimination of nuclear recoils from alpha particles with superheated liquids will most certainly appreciate the feedback.