Physics – Instrumentation and Detectors
Scientific paper
2003-10-10
Nucl.Instrum.Meth. A531 (2004) 467-480
Physics
Instrumentation and Detectors
Latex2e/elsart, 23 pages, 6 tables, 14 figures
Scientific paper
10.1016/j.nima.2004.05.094
A Shashlyk calorimeter prototype for the KOPIO experiment has been constructed and experimentally tested. The energy resolution of about 4%/sqrt(E(GeV)) for 0.5-2.0 GeV/c positrons was obtained. Based on this results as well as on the results of special measurements, a Monte-Carlo model of the Shashlyk module response was developed. This model, including the effects of shower evolution, light collection in scintillator plates, light attenuation in fibers, quantum efficiency of the photodetector, thresholds and noises in the readout system is consistent with experimental results. Possible improvment of the Shashlyk energy resolution up to 3%/sqrt(E(GeV)), the level required by KOPIO experiment, are discussed.
Atoian G. S.
Issakov Vladimir
Karavichev O. V.
Karavicheva T. L.
Poblaguev Andrei
No associations
LandOfFree
Development of Shashlyk Calorimeter for KOPIO does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Development of Shashlyk Calorimeter for KOPIO, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Development of Shashlyk Calorimeter for KOPIO will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-217121