Physics – Instrumentation and Detectors
Scientific paper
2011-06-10
Physics
Instrumentation and Detectors
This article has been submitted to Chinese Physics C
Scientific paper
A front-end readout electronics system has been developed for silicon strip detectors. The system uses an application specific integrated circuit (ASIC) ATHED to realize multi-channel E&T measurement. The slow control of ASIC chips is achieved by parallel port and the timing control signals of ASIC chips are provided by the CPLD. The data acquisition is implemented with a PXI-DAQ card. The system software has a user-friendly GUI which uses LabWindows/CVI in Windows XP operating system. Test results showed that the energy resolution is about 1.22 % for alphas at 5.48 MeV and the maximum channel crosstalk of system is 4.6%. The performance of the system is very reliable and suitable for nuclear physics experiments.
Dong Cheng-Fu
Kong Jason J.
Li Xiao-Gang
Ma Xiao-Li
Qian Yi
No associations
LandOfFree
Development of front-end readout electronics for silicon strip detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Development of front-end readout electronics for silicon strip detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Development of front-end readout electronics for silicon strip detectors will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-319754