Development of deuteron beam polarimeter at RCNP

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Polarized Beams, Nuclear Orientation Devices

Scientific paper

A polarimeter for a deuteron beam at 200 MeV has been developed at RCNP. The polarimeter uses the maximum values of Ayy and Ay of d+p scattering. The polarimeter Ayy was calibrated using theoretically-known analyzing powers of Ayy=-1/2(Azz=1) of 12C(dvec,α)10B2+ reaction at 0°. The beam vector polarization py was estimated using the rf transition probabilities in the atomic ion source. The polarimeter Ay was evaluated from the measured asymmetry pyAy and the estimated py. Uncertainties in the polarimeter Ay and Ayy are estimated to be about 2%. .

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Development of deuteron beam polarimeter at RCNP does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Development of deuteron beam polarimeter at RCNP, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Development of deuteron beam polarimeter at RCNP will most certainly appreciate the feedback.