We have completed a cryostat system using two stages 4K Gifford-MacMahon cryocoolers for a prototype of cryogenic laser interferometer settled in ICRR. The first cooling down and vibration measurement on a mirror chamber of the cryostat system have been done. Results shows that temperature in the mirror chamber of 9K and 10-5Pa vacuum pressure achieved after four days cooling down. No excess vibration peak under 10 Hz due to the cryocooler was found.