Physics
Scientific paper
Feb 2009
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2009chphc..33..119s&link_type=abstract
Chinese Physics C, Volume 33, Issue 2, pp. 119-122 (2009).
Physics
Scientific paper
A new kind (two end readout) of Multi-gap Resistive Plate Chamber with long readout-strip (LMRPC) is developed to be used at the large-area Muon Telescope Detector (MTD) at mid-rapidity at RHIC/STAR experiment for Time-of-Flight (TOF) measurement. The LMRPC has an active area of 87 cm × 17 cm, 10 gas gaps of 250 μm arranged in 2 stacks, with readout strips of 2.5 cm wide and 90 cm long. The considerations in LMRPC design related to its performance are discussed in this paper. The cosmic ray test results of a prototype LMRPC show a detection efficiency >95% and the time resolution ~70 ps.
Chen Hong-fang
Li Cheng
Shao Ming
Sun Yong-Jie
Zhao Yan-E.
No associations
LandOfFree
DETECTORS AND EXPERIMENTAL METHODS: Design and test of a Multi-gap Resistive Plate Chamber with Long readout-strip (LMRPC) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with DETECTORS AND EXPERIMENTAL METHODS: Design and test of a Multi-gap Resistive Plate Chamber with Long readout-strip (LMRPC), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and DETECTORS AND EXPERIMENTAL METHODS: Design and test of a Multi-gap Resistive Plate Chamber with Long readout-strip (LMRPC) will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-915362