Detector of alpha particles and x-rays operating in ambient air in pulse counting mode or/and with gas amplification

Physics – Instrumentation and Detectors

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

10.1088/1748-0221/3/02/P02006

Ionization chambers working in ambient air in current detection mode are widely used in several applications such as smoke detection, dosimetry, therapeutic beam monitoring and cetera. The aim of this work was to investigate if gaseous detectors can operate in ambient air in pulse counting mode as well as with gas amplification. . To investigate the feasibility of this method two types of open- end gaseous detectors were build and successfully tested. The first one was a single wire or multiwire cylindrical geometry detector operating in pulse mode at a gas gain of 1. The second type alpha detector was an innovative GEM-like detector with resistive electrodes operating in air in avalanche mode at high gas gains (up to 10E4). A detailed comparison between these two detectors is given as well as comparison with the commercially available alpha detectors. The main advantages of gaseous detectors operating in air in a pulse detection mode are their simplicity, low cost and high sensitivity. One of the possible applications of these new detectors is alpha particle background monitors which, due to their low cost can find wide application not only in houses, but in public areas: airports, railway station and so on.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Detector of alpha particles and x-rays operating in ambient air in pulse counting mode or/and with gas amplification does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Detector of alpha particles and x-rays operating in ambient air in pulse counting mode or/and with gas amplification, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Detector of alpha particles and x-rays operating in ambient air in pulse counting mode or/and with gas amplification will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-377867

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.