Physics – Optics
Scientific paper
Oct 2005
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2005spie.5964..280j&link_type=abstract
Advances in Optical Thin Films II. Edited by Amra, Claude; Kaiser, Norbert; Macleod, H. Angus. Proceedings of the SPIE, Volume
Physics
Optics
Scientific paper
A thermal camera consists of 1024-element MCT line wavelength IRFPA with reading electrocircuit made in china. It is presented the composing of this infrared thermal camera and some key question of this thermal camera: 1) nonuniformity correction; 2) Correction of lines and rows. With same axial transmission optics and a 1-D equality angle scanner and 1024X1600 pixels per frame.the scan efficiency of the sensor is over 88% and the half periods of scanner is 5 seconds. we developed a IR instrument. the main technic target is followed: optics calibre: 90 mm, focus: 270.6 mm, identifiaction ratio:170 urad, wave band: 2-2.5um, the half period: 5 second, NEΔρ: 0.8%.
Jian Xian Zhong
Zhang Su Ying
No associations
LandOfFree
Design of mct1024×1 short wave infrared thermal camera does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Design of mct1024×1 short wave infrared thermal camera, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Design of mct1024×1 short wave infrared thermal camera will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1658680