Physics
Scientific paper
Aug 2005
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2005spie.5904..321b&link_type=abstract
Cryogenic Optical Systems and Instruments XI. Edited by Heaney, James B.; Burriesci, Lawrence G. Proceedings of the SPIE, Volume
Physics
Scientific paper
This paper describes the design, manufacturing, modeling, and testing of a methane cryogenic diode heat pipe (CDHP) thermal switching system for the CRISM instrument onboard the NASA/JPL Mars Reconnaissance Orbiter. The purpose of the CDHP system is to enable three 1-year cryocoolers to provide 2 years of cooling to the 100 K CRISM sensor while minimizing the parasitic heat input from the two OFF (redundant) cryocoolers. Without the CDHP system, the parasitic heat input from the two OFF cryocoolers would prevent the CRISM sensor from being cooled to an acceptably low operating temperature. To provide sufficient structural support for launch with low parasitic heat input, the three methane CDHPs were supported by small diameter Kevlar tension cables attached to a shoebox-shaped cold shroud that enveloped the assembly. The cold shroud -- thermally coupled by a flexible link to the (cryoradiator cooled) cold side of the instrument housing -- was suspended from the warm side of the instrument housing by a second set of Kevlar cables, creating a dual-nested Kevlar cable thermal isolation/structural support system similar to that flown on the CRYOTSU flight experiment on STS-95. To accurately test the thermal switching system, a novel laboratory set-up was utilized involving three parallel heat metering cryocooler simulators (Q-meters). Numerous test runs were carried out to evaluate the impact of various system operating parameters. The parasitic heat leak predictions corresponded very closely to the measured data. The paper describes the effort from concept development through test data analysis.
Beres Matthew
Bugby David
Garzon Jessica
Mehoke Douglas
Stouffer Charles
No associations
LandOfFree
Cryogenic diode heat pipe system for cryocooler redundancy does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Cryogenic diode heat pipe system for cryocooler redundancy, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Cryogenic diode heat pipe system for cryocooler redundancy will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-802453