The Herschel Space Observatory (formerly known as FIRST) consists of a 3.5 m space telescope. As part of a JPL- funded effort to develop lightweight telescope technology suitable for this mission, COI designed and fabricated a spherical, F/1, 2 m aperture prototype primary mirror using solely carbon fiber reinforced polymer (CFRP) materials. To assess the performance of this technology, optical metrology of the mirror surface was performed from ambient to an intended operational temperature for IR-telescopes of 70K. Testing was performed horizontally in a cryogenic vacuum chamber at Arnold Engineering Development Center (AEDC), Tennessee. The test incorporated a custom thermal shroud, a characterization and monitoring of the dynamic environment, and a stress free mirror mount. An IR-wavelength phase shifting interferometer (IR PSI) was the primary instrument used to measure the mirror surface. From an initial surface figure of 2.1 microns RMS at ambient, a modest 3.9 microns of additional RMS surface error was induced at 70K. The thermally induced error was dominated by low-order deformations, of the type that could easily be corrected with secondary or tertiary optics. In addition to exceptional thermal stability, the mirror exhibited no significant change in the figure upon returning to room temperature.
Backovsky Stan
Barber Daniel D.
Catanzaro Brian E.
Cohen Eri J.
Connell Steven J.
No associations
LandOfFree
Cryogenic (70-K) measurement of an all-composite 2-m-diameter mirror does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Cryogenic (70-K) measurement of an all-composite 2-m-diameter mirror, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Cryogenic (70-K) measurement of an all-composite 2-m-diameter mirror will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1566971