Count rate dependent non-linearity and pixel size variations in 1.7 micron cut-off detectors

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Over the past decade scientists have collected convincing evidence that the content of our universe is dominated by a mysterious dark energy. Understanding the nature of dark energy is a very difficult task, and requires a variety of independent experimental approaches. Most of these approaches rely on photometric calibrations over a wide range of intensities using standardized stars and internal reference sources, and hence on a complete understanding of the linearity of the detectors. The SNAP near infrared (NIR) instrument team has performed a comprehensive study of precision photometry on 1.7 micron cut-off HgCdTe detectors. Among those studies are the count rate dependent detector non-linearity that was recently discovered with the NICMOS array on the Hubble Space Telescope, and possible pixel size variations seen in quantum efficiency (QE) data. The nonlinearity on NICMOS exhibits an unexpected behavior, where pixels with high (low) count rates detect slightly more (less) flux than expected for a linear system. To test this count rate dependent non-linearity a dedicated setup was built that produces a known amount of light on a detector, and measures its response as a function of light intensity and wavelength. If the pixel response variations seen in QE data are due to pixel area variations, standard flat-fielding will degrade photometry precision for point sources in an undersampled telescope. Studies have been performed to estimate the magnitude of pixel area variations.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Count rate dependent non-linearity and pixel size variations in 1.7 micron cut-off detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Count rate dependent non-linearity and pixel size variations in 1.7 micron cut-off detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Count rate dependent non-linearity and pixel size variations in 1.7 micron cut-off detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1061938

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.