The method to calculate the non-linearity correction of the electromagnetic calorimeter response, based on minimisation of the deviation of the measured neutral meson mass on the energies of it decay photons, is described in this paper. This method was developed for the electromagnetic calorimeter LGD2 in the Hyperon-M experiment at U70 accelerator of IHEP. The found correction allowed to reduce significantly variations of the reconstructed $\pi^0$ and $\eta$ masses on the minimal energy of the mesons.
Bogolyubsky Yu. M.
Kharlov Yu. V.
Patalakha D. I.
Polishchuk B. V.
Sadovsky S. A.
No associations
LandOfFree
Correction of the energy scale nonlinearity in electromagnetic calorimeters with the pi0 two-photon decays does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Correction of the energy scale nonlinearity in electromagnetic calorimeters with the pi0 two-photon decays, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Correction of the energy scale nonlinearity in electromagnetic calorimeters with the pi0 two-photon decays will most certainly appreciate the feedback.