Constraints on photon pulse duration from longitudinal electron beam diagnostics at a soft X-ray free-electron laser

Physics – Accelerator Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

12 pages, 9 figures, accepted for publication in Phys. Rev. ST Accel. Beams

Scientific paper

10.1103/PhysRevSTAB.15.030707

The successful operation of X-ray free-electron lasers (FELs), like the Linac Coherent Light Source or the Free-Electron Laser in Hamburg (FLASH), makes unprecedented research on matter at atomic length and ultrafast time scales possible. However, in order to take advantage of these unique light sources and to meet the strict requirements of many experiments in photon science, FEL photon pulse durations need to be known and tunable. This can be achieved by controlling the FEL driving electron beams, and high-resolution longitudinal electron beam diagnostics can be utilized to provide constraints on the expected FEL photon pulse durations. In this paper, we present comparative measurements of soft X-ray pulse durations and electron bunch lengths at FLASH. The soft X-ray pulse durations were measured by FEL radiation pulse energy statistics and compared to electron bunch lengths determined by frequency-domain spectroscopy of coherent transition radiation in the terahertz range and time-domain longitudinal phase space measurements. The experimental results, theoretical considerations, and simulations show that high-resolution longitudinal electron beam diagnostics provide reasonable constraints on the expected FEL photon pulse durations. In addition, we demonstrated the generation of soft X-ray pulses with durations below 50 fs (FWHM) after the implementation of the new uniform electron bunch compression scheme used at FLASH.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Constraints on photon pulse duration from longitudinal electron beam diagnostics at a soft X-ray free-electron laser does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Constraints on photon pulse duration from longitudinal electron beam diagnostics at a soft X-ray free-electron laser, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Constraints on photon pulse duration from longitudinal electron beam diagnostics at a soft X-ray free-electron laser will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-321066

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.