Compton imager using room temperature silicon detectors

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

3

X- And Gamma-Ray Telescopes And Instrumentation, Tracking And Position-Sensitive Detectors, Solid-State Detectors, X- And Gamma-Ray Spectroscopy, X- And Gamma-Ray Instruments

Scientific paper

We have been developing a multi-layer Compton Gamma Ray Imager using position-sensitive, intrinsic silicon detectors. Advantages of this approach include room temperature operation, reduced Doppler broadening, and use of conventional silicon fabrication technologies. We have obtained results on the imaging performance of a multi-layer instrument where each layer consists of a 2×2 array of double-sided strip detectors. Each detector is 63 mm×63 mm×2 mm thick and has 64 strips providing a strip pitch of approximately 0.9 mm. The detectors were fabricated by SINTEF ICT (Oslo Norway) from 100 mm diameter wafers. The use of large arrays of silicon detectors appears especially advantageous for applications that require excellent sensitivity, spectral resolution and imaging such as gamma ray astrophysics, detection of special nuclear materials, and medical imaging. The multiple Compton interactions (three or more) in the low-Z silicon enable the energy and direction of the incident gamma ray to be determined without full deposition of the incident gamma-ray energy in the detector. The performance of large volume instruments for various applications are presented, including an instrument under consideration for NASA's Advanced Compton Telescope (ACT) mission and applications to Homeland Security. Technology developments that could further extend the sensitivity and performance of silicon Compton Imagers are presented, including the use of low-energy (few hundred keV) electron tracking within novel silicon detectors and the potential for a wafer-bonding approach to produce thicker, position-sensitive silicon detectors with an associated reduction of required electronics and instrument cost.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Compton imager using room temperature silicon detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Compton imager using room temperature silicon detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Compton imager using room temperature silicon detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1795942

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.