Timing characteristics of two multigap RPCs were compared. One had four subgaps 0.3 mm wide and the other - two subgaps 0.6 mm wide. Specially developed electronics was used. Electronics resolution convoluted with measured charge spectra at operating point was estimated as about 65 ps. The best time resolutions obtained at low counting rate were 75 ps for the 0.3 mm subgap and about 125 ps for the 0.6 mm one, after slewing corrections. The rate capability of the (2x0.6mm) counter was found to be considerably lower than for the (2x(2x0.3mm)) one.
Ammosov Vladimir
Gapienko V.
Ivanilov A. A.
Semak A.
Sviridov Yu.
No associations
LandOfFree
Comparison of Timing Properties of Glass Multigap RPCs with 0.3 and 0.6 mm Subgap Width does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Comparison of Timing Properties of Glass Multigap RPCs with 0.3 and 0.6 mm Subgap Width, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Comparison of Timing Properties of Glass Multigap RPCs with 0.3 and 0.6 mm Subgap Width will most certainly appreciate the feedback.