Comparison of Error Estimations by DERs in One-Port S and SLO Calibrated VNA Measurements and Application

Physics – Instrumentation and Detectors

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

4 pages, 9 figures, 3 references - Accepted for Publication to 21st International Conference Radioelektronika 2011, April 19-2

Scientific paper

In order to demonstrate the usefulness of the only one existing method for systematic error estimations in VNA (Vector Network Analyzer) measurements by using complex DERs (Differential Error Regions), we compare one-port VNA measurements after the two well-known calibration techniques: the quick reflection response, that uses only a single S (Short circuit) standard, and the time-consuming full one-port, that uses a triple of SLO standards (Short circuit, matching Load, Open circuit). For both calibration techniques, the comparison concerns: (a) a 3D geometric representation of the difference between VNA readings and measurements, and (b) a number of presentation figures for the DERs and their polar DEIs (Differential Error Intervals) of the reflection coefficient, as well as, the DERs and their rectangular DEIs of the corresponding input impedance. In this paper, we present the application of this method to an AUT (Antenna Under Test) selected to highlight the existence of practical cases in which the time consuming calibration technique results a systematic error estimation stripe including almost all of that of quick calibration.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Comparison of Error Estimations by DERs in One-Port S and SLO Calibrated VNA Measurements and Application does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Comparison of Error Estimations by DERs in One-Port S and SLO Calibrated VNA Measurements and Application, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Comparison of Error Estimations by DERs in One-Port S and SLO Calibrated VNA Measurements and Application will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-520825

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.