Astronomy and Astrophysics – Astrophysics
Scientific paper
Jan 1992
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1992spie.1546....2k&link_type=abstract
In: Multilayer and grazing incidence X-ray/EUV optics; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991 (A93-39658 15
Astronomy and Astrophysics
Astrophysics
Grazing Incidence, Image Resolution, Instrument Compensation, Test Facilities, X Ray Astrophysics Facility, X Ray Detectors, High Resolution, Microchannel Plates, Mirrors, X Ray Imagery
Scientific paper
Advanced X-ray Astrophysics Facility (AXAF) X-ray optics testing is conducted by VETA-I, which consists of six nested Wolter type I grazing-incidence mirrors; VETA's X-ray Detection System (VXDS) in turn measures the imaging properties of VETA-I, yielding FWHM and encircled energy of the X-ray image obtained, as well as its effective area. VXDS contains a high resolution microchannel plate imaging X-ray detector and a pinhole scanning system in front of proportional-counter detectors. VETA-I's X-ray optics departs from the AXAF flight configuration in that it uses a temporary holding fixture; its mirror elements are not cut to final length, and are not coated with the metal film used to maximize high-energy reflection.
Brissenden Roger
Flanagan Katherine
Freeman Mark
Hughes Jacob
Jones Malcolm
No associations
LandOfFree
Calibration of the Verification Engineering Test Article-I (VETA-I) for AXAF using the VETA-I X-ray Detection System does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Calibration of the Verification Engineering Test Article-I (VETA-I) for AXAF using the VETA-I X-ray Detection System, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Calibration of the Verification Engineering Test Article-I (VETA-I) for AXAF using the VETA-I X-ray Detection System will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-940907