The quenching factor of cesium and iodine nuclei recoiling in a CsI(Tl) scintillator is measured by scattering of 3 to 6 MeV neutrons. This factor increases when recoil energy decreases, from 7% at 150 keV to 15% at 25 keV. This relatively high efficiency could be useful in experiments dealing with very low recoil energies like the WIMP direct detection. These values are well explained by the Birks model. Pulse shape discrimination between electron and nuclei recoils is also investigated. Results are sufficiently good to allow a significant statistical rejection of radioactive background. This rejection capability is shown to be better than for NaI(Tl), at the same electron equivalent energy.
Chambon B.
de Jesus Maryvonne
Drain D.
Gerbier Gilles
Mallet J.
No associations
LandOfFree
Calibration of a CsI(Tl) crystal with nuclear recoils and pulse shape measurements for dark matter detection does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Calibration of a CsI(Tl) crystal with nuclear recoils and pulse shape measurements for dark matter detection, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Calibration of a CsI(Tl) crystal with nuclear recoils and pulse shape measurements for dark matter detection will most certainly appreciate the feedback.