Beam Orientation Optimization for Intensity Modulated Radiation Therapy using Adaptive l1 Minimization

Physics – Medical Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

19 pages, 2 tables, and 5 figures

Scientific paper

Beam orientation optimization (BOO) is a key component in the process of IMRT treatment planning. It determines to what degree one can achieve a good treatment plan quality in the subsequent plan optimization process. In this paper, we have developed a BOO algorithm via adaptive l_1 minimization. Specifically, we introduce a sparsity energy function term into our model which contains weighting factors for each beam angle adaptively adjusted during the optimization process. Such an energy term favors small number of beam angles. By optimizing a total energy function containing a dosimetric term and the sparsity term, we are able to identify the unimportant beam angles and gradually remove them without largely sacrificing the dosimetric objective. In one typical prostate case, the convergence property of our algorithm, as well as the how the beam angles are selected during the optimization process, is demonstrated. Fluence map optimization (FMO) is then performed based on the optimized beam angles. The resulted plan quality is presented and found to be better than that obtained from unoptimized (equiangular) beam orientations. We have further systematically validated our algorithm in the contexts of 5-9 coplanar beams for 5 prostate cases and 1 head and neck case. For each case, the final FMO objective function value is used to compare the optimized beam orientations and the equiangular ones. It is found that, our BOO algorithm can lead to beam configurations which attain lower FMO objective function values than corresponding equiangular cases, indicating the effectiveness of our BOO algorithm.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Beam Orientation Optimization for Intensity Modulated Radiation Therapy using Adaptive l1 Minimization does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Beam Orientation Optimization for Intensity Modulated Radiation Therapy using Adaptive l1 Minimization, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Beam Orientation Optimization for Intensity Modulated Radiation Therapy using Adaptive l1 Minimization will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-284906

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.