The AXAF VETA-I mirror ring focus measurements were made with a HRI (microchannel plate) X-ray detector. The ring focus is a sharply focused ring formed by X-rays before they reach the VETA-I focal plane. It is caused by spherical aberrations due to the finite source distance and the despace in the VETA-I test. The ring focus test reveals some aspects of the test system distortions and the mirror surface figure which are difficult or impossible to detect at the focal plane. The test results show periodic modulations of the ring radius and width which could be caused by gravity, thermal, and/or epoxy shrinkage distortions. We expect that a similar test for the finally assembled mirror of AXAF-I will be highly valuable.
Freeman Mark D.
Jerius Diab
Shao Yibo
Zhao Ping
No associations
LandOfFree
AXAF VETA-I mirror ring focus measurements does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with AXAF VETA-I mirror ring focus measurements, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and AXAF VETA-I mirror ring focus measurements will most certainly appreciate the feedback.