Cryogenic pressure control valves were designed, developed, and qualified for the third stage of the Ariane launch vehicle. Design drivers include accurate pressure control and operation under conditions of vibration, acceleration, and +30 to -223 deg C temperatures. The methods by which the required performance was achieved are presented together with typical test data. The development and qualification programs are reviewed.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Ariane 3rd stage pressure control valves does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Ariane 3rd stage pressure control valves, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Ariane 3rd stage pressure control valves will most certainly appreciate the feedback.