Analytical Approach to the Local Contact Potential Difference on (001) Ionic Surfaces: Implications for Kelvin Probe Force Microscopy

Physics – Atomic and Molecular Clusters

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

10.1103/PhysRevB.78.035410

An analytical model of the electrostatic force between the tip of a non-contact Atomic Force Microscope (nc-AFM) and the (001) surface of an ionic crystal is reported. The model is able to account for the atomic contrast of the local contact potential difference (CPD) observed while nc-AFM-based Kelvin Probe Force Microscopy (KPFM) experiments. With the goal in mind to put in evidence this short-range electrostatic force, the Madelung potential arising at the surface of the ionic crystal is primarily derived. The expression of the force which is deduced can be split into two major contributions: the first stands for the coupling between the microscopic structure of the tip apex and the capacitor formed between the tip, the ionic crystal and the counter-electrode; the second term depicts the influence of the Madelung surface potential on the mesoscopic part of the tip, independently from its microscopic structure. These short-range electrostatic forces are in the range of ten pico-Newtons. When explicitly considering the crystal polarization, an analytical expression of the bias voltage to be applied on the tip to compensate for the local CPD, i.e. to cancel the short-range electrostatic force, is derived. The compensated CPD has the lateral periodicity of the Madelung surface potential. However, the strong dependence on the tip geometry, the applied modulation voltage as well as the tip-sample distance, which can even lead to an overestimation of the real surface potential, makes quantitative KPFM measurements of the local CPD extremely difficult.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Analytical Approach to the Local Contact Potential Difference on (001) Ionic Surfaces: Implications for Kelvin Probe Force Microscopy does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Analytical Approach to the Local Contact Potential Difference on (001) Ionic Surfaces: Implications for Kelvin Probe Force Microscopy, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Analytical Approach to the Local Contact Potential Difference on (001) Ionic Surfaces: Implications for Kelvin Probe Force Microscopy will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-687899

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.