Physics
Scientific paper
Mar 2004
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2004cqgra..21s.441g&link_type=abstract
Classical and Quantum Gravity, Volume 21, Issue 5, pp. S441-S449 (2004).
Physics
6
Scientific paper
We give an overview of the automatic mirror alignment system of the gravitational wave detector GEO 600. In order to achieve the required sensitivity of the Michelson interferometer, the axes of interfering beams have to be superimposed with a residual angle of the order 10-8 rad. The beam spots have to be centred on the mirrors to minimize coupling of alignment noise into longitudinal signals. We present the actual control topology and results from the system in operation, which controls all alignment degrees of the power-recycled Michelson. With this system continuous lock stretches of more than 121 h duration were achieved.
Casey Martin
Danzmannx K.
Freise Andreas
Goßler Stefan
Grote Hartmut
No associations
LandOfFree
Alignment control of GEO 600 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Alignment control of GEO 600, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Alignment control of GEO 600 will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1131534