The 336-actuator adaptive secondary unit (MMT336) for the new MMT is being assembled in Italy and will be delivered in June 2000 for the acceptance test at Steward Observatory (Tucson, AZ). The latest results obtained on a reduced-size (36 actuators) prototype called P36 are reported, confirming a settling time less than 1 ms measured in previous tests. The flattening procedure has been successfully tested on the P36 unit, reducing the initial surface error of 1.1 micrometer down to 43 nm rms. Moreover the dynamical tests on the P36 unit show that the system is able to attenuate the atmospheric-induced error from 466 nm to 31 nm rms. This in the case of median seeing condition at MMT (0.75 arcsec) a high wind speed (48 m/s) and a 1 kHz command rate per actuator. Finally, in the same conditions the atmospheric error is effectively attenuated up to a frequency of 100 Hz (OdB attenuation level).
Andrighettoni Mario
Biasi Roberto
Biliotti Valdemaro
Brusa Guido
Del Vecchio Ciro
No associations
LandOfFree
Adaptive secondary mirror for the 6.5-m conversion of the Multiple Mirror Telescope: latest laboratory test results of the P36 prototype does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Adaptive secondary mirror for the 6.5-m conversion of the Multiple Mirror Telescope: latest laboratory test results of the P36 prototype, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Adaptive secondary mirror for the 6.5-m conversion of the Multiple Mirror Telescope: latest laboratory test results of the P36 prototype will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1481163