In the design of a large adaptive deformable membrane mirror, variable reluctance actuators are used. These consist of a closed magnetic circuit in which a strong permanent magnet provides a static magnetic force on a ferromagnetic core which is suspended in a membrane. By applying a current through the coil which is situated around the magnet, this force is influenced, providing movement of the ferromagnetic core. This movement is transferred via a rod imposing the out-of-plane displacements in the reflective deformable membrane. In the actuator design a match is made between the negative stiffness of the magnet and the positive stiffness of the membrane suspension. If the locality of the influence functions, mirror modes as well as force and power dissipation are taken into account, a resonance frequency of 1500 Hz and an overall stiffness of 1000 N/m for the actuators is needed. The actuators are fabricated and the dynamic response tested in a dedicated setup. The Bode diagram shows a first eigenfrequency of 950 Hz. This is due to a lower magnetic force than expected. A Helmholtz coil setup was designed to measure the differences in a large set of permanent magnets. With the same setup the 2nd quadrant of the B-H curve is reconstructed by stacking of the magnets and using the demagnetization factor. It is shown that the values for Hc and Br of the magnets are indeed lower than the values used for the initial design. New actuators, with increased magnet thickness, are designed and currently fabricated.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Actuator tests for a large deformable membrane mirror does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Actuator tests for a large deformable membrane mirror, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Actuator tests for a large deformable membrane mirror will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1625896

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.