Accurate photometry with adaptive optics in the presence of anisoplanatic effects with a sparsely sampled PSF. The Galactic center as an example of a challenging target for accurate AO photometry

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

6

Techniques: Image Processing, Instrumentation: High, Angular Resolution, Instrumentation: Adaptive Optics, Methods:, Data Analysis, Methods: Observational, Galaxy: Center

Scientific paper

Context. Anisoplanatic effects can cause significant systematic photometric uncertainty in the analysis of dense stellar fields observed with adaptive optics. Program packages have been developed for a spatially variable PSF, but they require that a sufficient number of bright, isolated stars in the image are present to adequately sample the PSF. Aims: Imaging the Galactic center is particularly challenging. We present two ways of dealing with spatially variable PSFs when only one or very few suitable PSF reference stars are present in the field. Methods: Local PSF fitting with the StarFinder algorithm is applied to the data. Satisfying results can be found in two ways: (a) creating local PSFs by merging locally extracted PSF cores with the PSF wings estimated from the brightest star in the field; (b) Wiener deconvolution of the image with the PSF estimated from the brightest star in the field and subsequent estimation of local PSFs on the deconvolved image. The methodology is tested on real, and on artificial images. Results: The method involving Wiener deconvolution of the image prior to local PSF extraction and fitting gives excellent results. It limits systematic effects to ~2-5% in point source photometry and ~10% in diffuse emission on fields-of-view as large as 28 arcsec ×28 arcsec and observed through the H-band filter. Particular attention is given to how deconvolution changes the noise properties of the image. It is shown that mean positions and fluxes of the stars are conserved by the deconvolution. However, the estimated uncertainties of the PSF fitting algorithm are too small if the presence of covariances is ignored in the PSF fitting as has been done here. An appropriate scaling factor can, however, be determined from simulated images or by comparing measurements on independent data sets. Conclusions: We present ways of obtaining reliable photometry and astrometry from images with a spatially variable, but poorly sampled PSF, where standard techniques may not work.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Accurate photometry with adaptive optics in the presence of anisoplanatic effects with a sparsely sampled PSF. The Galactic center as an example of a challenging target for accurate AO photometry does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Accurate photometry with adaptive optics in the presence of anisoplanatic effects with a sparsely sampled PSF. The Galactic center as an example of a challenging target for accurate AO photometry, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Accurate photometry with adaptive optics in the presence of anisoplanatic effects with a sparsely sampled PSF. The Galactic center as an example of a challenging target for accurate AO photometry will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-960745

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.