Physics – Instrumentation and Detectors
Scientific paper
2009-01-30
Physics
Instrumentation and Detectors
Scientific paper
We present measurements with a GEM based TPC prototypes and the TimePix CMOS ASIC as charge collecting anode. Tests with a small prototype were performed in a 5 GeV electron beam at DESY. Different GEM orientations and geometries were tested. It is shown that the point resolution for short drift distances is better than 20 micrometer. The achieved time resolution is better than 10 ns at 100 MHz clock frequency. Furthermore, experimental studies with an enlarged pixel size are addressed. To study the performance for longer drift distances a chamber with 26 cm drift length is operated in Bonn. Using also GEM and TimePix for the readout, data with cosmic muons and a Sr90 source are recorded. The spatial resolution and cluster properties are studied in dependence on the drift distance.
No associations
LandOfFree
A TPC with Triple-GEM Gas Amplification and TimePix Readout does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with A TPC with Triple-GEM Gas Amplification and TimePix Readout, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A TPC with Triple-GEM Gas Amplification and TimePix Readout will most certainly appreciate the feedback.