A study of the effects of transducer size on physical modeling experiments for recovering anisotropic elastic parameters

Physics – Geophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Electromagnetics: Wave Propagation, Exploration Geophysics, Exploration Geophysics: Seismic Methods, Exploration Geophysics: Instruments And Techniques

Scientific paper

The effect of finite size transducers on elastic parameters recovered from laboratory measurements has been studied in this paper. Ultrasonic transmission experiments in the physical modeling laboratory were used to acquire the first arrival traveltime data at different ray angles, to simulate walkaway VSP surveys in the field. The elastic parameters of the materials were then recovered by our developed inversion techniques, using velocities at different directions inverted from the first arrival traveltimes. In our laboratory experiments, ``point'' transducers and ``large'' transducers were used to carry out the transmission experiments. The finite size of the transducers introduced systematic errors in the first break picks along the survey line, and hence the determined velocity field was inaccurate. These systematic errors cannot be corrected by the inversion technique. Numerical simulations were also conducted to study the differences between experiments using large and point transducers. From our experimental measurements, accurate elastic parameter values are obtained when the ratio of the sample-thickness to transducer-diameter is greater than 36. Decreasing the size of the transducers is highly recommended when conducting laboratory experiments to recover elastic parameters. A method of offset correction is also implemented in an attempt to decrease the measurement errors.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A study of the effects of transducer size on physical modeling experiments for recovering anisotropic elastic parameters does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A study of the effects of transducer size on physical modeling experiments for recovering anisotropic elastic parameters, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A study of the effects of transducer size on physical modeling experiments for recovering anisotropic elastic parameters will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1611123

  Search