A Reflective Gaussian Coronagraph for Extreme Adaptive Optics: Laboratory Performance

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2

Instrumentation: Adaptive Optics, Stars: Planetary Systems

Scientific paper

We report laboratory results of a coronagraphic test bench to assess the intensity reduction differences between a ``Gaussian'' tapered focal plane coronagraphic mask and a classical hard-edged ``top hat'' function mask at extreme adaptive optics (ExAO) Strehl ratios of ~94%. However, unlike a traditional coronagraph design, we insert a reflective focal plane mask at 45° to the optical axis. We also use an intermediate secondary mask (mask 2) before a final image in order to block additional mask-edge-diffracted light. The test bench simulates the optical train of ground-based telescopes (in particular, the 8.1 m Gemini North Telescope). It includes one spider vane, different mask radii (r = 1.9λ/D, 3.7λ/D, and 7.4λ/D), and two types of reflective focal plane masks (hard-edged top-hat and Gaussian tapered profiles). In order to investigate the relative performance of these competing coronagraphic designs with regard to extrasolar planet detection sensitivity, we utilize the simulation of realistic extrasolar planet populations (Nielsen et al.). With an appropriate translation of our laboratory results to expected telescope performance, a Gaussian tapered mask radius of 3.7λ/D with an additional mask (mask 2) performs best (highest planet detection sensitivity). For a full survey with this optimal design, the simulation predicts that ~30% more planets would be detected than with a top-hat function mask of similar size with mask 2. Using the best design, the point contrast ratio between the stellar point-spread function (PSF) peak and the coronagraphic PSF at 10λ/D (0.4" in the H band if D = 8.1 m) is ~10 times higher than a classical Lyot top-hat coronagraph. Hence, we find that a Gaussian apodized mask with an additional blocking mask is superior (~10 times higher contrast) to the use of a classical Lyot coronagraph for ExAO-like Strehl ratios.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A Reflective Gaussian Coronagraph for Extreme Adaptive Optics: Laboratory Performance does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A Reflective Gaussian Coronagraph for Extreme Adaptive Optics: Laboratory Performance, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A Reflective Gaussian Coronagraph for Extreme Adaptive Optics: Laboratory Performance will most certainly appreciate the feedback.