A Readout System for the STAR Time Projection Chamber

Physics – Nuclear Physics – Nuclear Experiment

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

22 pages + 8 separate figures; 2 figures are .jpg photos to appear in Nuclear Instruments and Methods

Scientific paper

10.1016/S0168-9002(02)01965-4

We describe the readout electronics for the STAR Time Projection Chamber. The system is made up of 136,608 channels of waveform digitizer, each sampling 512 time samples at 6-12 Mega-samples per second. The noise level is about 1000 electrons, and the dynamic range is 800:1, allowing for good energy loss ($dE/dx$) measurement for particles with energy losses up to 40 times minimum ionizing. The system is functioning well, with more than 99% of the channels working within specifications.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A Readout System for the STAR Time Projection Chamber does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A Readout System for the STAR Time Projection Chamber, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A Readout System for the STAR Time Projection Chamber will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-32862

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.