A novel readout method for focal plane array imaging in the presence of large dark current

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Optical Imaging

Scientific paper

This research was an investigation of a novel readout method for focal plane array (FPA) optical imaging, especially for very sensitive detectors with large dark current. The readout method is based on periodically blocking the optical input enabling the removal of the dark current integration from the output. The research demonstrated that it is feasible to modulate the optical input with the designed readout circuit and thus achieve longer signal integration time to enhance the signal-to- noise ratio. Study of a proposed circuit model showed that in theory the correlated readout method could increase the output voltage swing and reduce the noise level by attenuating low frequency noise, thereby effectively improving the FPA dynamic range. Circuits based on standard CMOS circuitry were designed, simulated by PSpice, fabricated using Orbit 2μm n-well technology, and tested with a PI-4000 system. In the circuit evaluation, the output noise due to the clock switching phenomena, the gate signal feedthrough and the charge relaxation, was considered to be the critical problem. The most promising design for minimizing this problem had a CMOS current steering circuit at the input of a high CMRR operational amplifier. Simulation and test results showed that a modified capacitive transimpedance amplifier (CTIA) could subtract dark current output and reduce the output signal due to any difference between the frequencies of the optical input modulation signal and the switch modulation signal. In conclusion, the correlated readout circuit was shown to be a promising approach for advancing FPA technology.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A novel readout method for focal plane array imaging in the presence of large dark current does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A novel readout method for focal plane array imaging in the presence of large dark current, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A novel readout method for focal plane array imaging in the presence of large dark current will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1017145

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.