Physics
Scientific paper
Feb 1996
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1996nimpa.381...49c&link_type=abstract
Nuclear Instruments and Methods in Physics Research Section A, v. 381, p. 49-56.
Physics
12
Scientific paper
A compact and portable beam telescope has been built using four 1.92 × 1.92 cm2 double sided silicon microstrip detectors with 50 μm read-out pitch. Tests using 50 GeV pions have shown that the beam position can be defined with a precision of 5 and 7 μm on the p-side and n-side respectively with an overall detection efficiency of 93.0%.
Celano L.
Creanza D.
de Palma M.
Fiore L.
Maggi G.
No associations
LandOfFree
A high resolution beam telescope built with double sided silicon strip detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with A high resolution beam telescope built with double sided silicon strip detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A high resolution beam telescope built with double sided silicon strip detectors will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-855393