Physics – Instrumentation and Detectors
Scientific paper
2008-11-26
J.Appl.Phys.103:094912,2008
Physics
Instrumentation and Detectors
Scientific paper
10.1063/1.2913331
Proof-of-principle experiments have demonstrated an electrostatic field evaporation based deuterium ion source for use in compact, high-output deuterium-tritium neutron generators. The ion source produces principally atomic deuterium and titanium ions. More than 100 monolayers of deuterated titanium thin film can be removed and ionized from a single tip in less than 20 ns. The measurements indicate that with the use of microfabricated tip arrays the deuterium ion source could provide sufficient ion current to produce 10^9 to 10^10 n/cm^2 of tip array area.
Reichenbach Birk
Schwoebel P. R.
Solano I.
No associations
LandOfFree
A field evaporation deuterium ion source for neutron generators does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with A field evaporation deuterium ion source for neutron generators, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A field evaporation deuterium ion source for neutron generators will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-273724