Physics
Scientific paper
Jan 2000
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2000nimpa.439..560k&link_type=abstract
Nuclear Instruments and Methods in Physics Research Section A, Volume 439, Issue 2-3, p. 560-566.
Physics
1
Scientific paper
Charge transfer loss due to deep level traps in CCDs is a common phenomenon. In single-photon counting CCDs for X-ray detection, the charge loss results in a degradation of spectroscopic resolution. The transfer loss of a signal depends on various parameters like temperature, number of transferred charges, number of charges in the preceding signals and the elapsed time between these signals. Each signal has to be corrected individually with respect to these parameters. An algorithm based on first principles of capture and emission, that allows a fast determination of the transfer loss is presented. The model was tested on calibration data of an X-ray pn-CCD of the EPIC consortium for XMM. The model describes the experimental data very well.
Briel Ulrich G.
Krause Nathalie
Popp Markus
Soltau Heike
Stadlbauer T.
No associations
LandOfFree
A fast calculation algorithm for the charge transfer loss in CCDs does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with A fast calculation algorithm for the charge transfer loss in CCDs, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A fast calculation algorithm for the charge transfer loss in CCDs will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-809563