Physics – Instrumentation and Detectors
Scientific paper
2009-01-28
Physics
Instrumentation and Detectors
4 pages, 5 figures, to appear in the proceedings of the LCWS08 conference
Scientific paper
Progress is reported on the development and testing of Monolithic Active Pixel Sensors (MAPS) for a Si-W ECAL for the ILC. Using laser and source setups, a first version of the sensor has been characterised through measurements of the absolute gain calibration, noise and pedestal. The pixel-to-pixel gain spread is 10%. Charge diffusion has been measured and found to be compatible with simulation results. The charge collected by a single pixel varies from 50% to 20% depending on where it is generated. After adding detector effects to the Geant4 simulation of an ILC-like ECAL, using the measured parameters, the energy resolution is found to be 35% higher than the ideal resolution, but is still lower than the resolution obtained for an equivalent analogue ECAL.
Ballin J. A.
Crooks J. P.
Dauncey P. D.
Magnan A.-M.
Mikami Yoshitaka
No associations
LandOfFree
A digital ECAL based on MAPS does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with A digital ECAL based on MAPS, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A digital ECAL based on MAPS will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-344804