A calibration neutron monitor: Energy response and instrumental temperature sensitivity

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

4

Interplanetary Physics: Cosmic Rays, Interplanetary Physics: Heliopause And Solar Wind Termination, Interplanetary Physics: Energetic Particles (7514), Interplanetary Physics: General Or Miscellaneous, Interplanetary Physics: Instruments And Techniques

Scientific paper

Neutron monitors are integral detectors of secondary cosmic rays. Since each of them has its own detection efficiency, energy spectra cannot readily be derived from their observations. To circumvent this problem, latitudinal surveys have been conducted for many years with mobile neutron monitors to derive such spectra. Another way, however, is to use the worldwide stationary neutron monitor network, but then the counting rates of these monitors must be normalized sufficiently accurately against one another. For this reason, two portable calibration neutron monitors were built at the Potchefstroom campus of the North-West University, South Africa. When calibrations of an adequate number of the worldwide neutron monitors have been done, this paper demonstrates that the differential response functions derived from them will provide experimental data for modulation studies in the rigidity range of 1 to 15 GV. Several properties of these calibrators were investigated, in order to achieve sufficient calibration accuracy. The energy response over the cutoff rigidity range from the poles to the equator, as well as the instrumental temperature sensitivity, are described in this paper. The main conclusion is that the calibrator has a difference of almost 4% in its energy response over the cutoff rigidity range 0-16 GV in comparison with a standard 3NM64 neutron monitor. Furthermore, it is shown that not only the calibrator, but also the NM64 and IGY monitors, have fairly large instrumental temperature sensitivities. Correction coefficients for these effects are given.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A calibration neutron monitor: Energy response and instrumental temperature sensitivity does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A calibration neutron monitor: Energy response and instrumental temperature sensitivity, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A calibration neutron monitor: Energy response and instrumental temperature sensitivity will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1861288

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.