We present results of studies made with a reduced-scale water Cerenkov detector (WCD) prototype for the Pierre Auger Observatory. This detector is made of high-density polyethylene and was operated continuously for four months. We studied time variations in the amplitude and shape of Cerenkov pulses due to cosmic ray muons and studied the correlation of these parameters with the bacterial population of the water. We also developed and tested a new technique to calibrate and monitor WCDs remotely, based on muons stopping and decaying inside the tank. We conclude that high-density polyethylene tanks fulfill the requirements for use in the water Cerenkov detectors of the Pierre Auger Observatory.
D'Olivo Juan Carlos
Fernandez Alberto
Medina Moti
Nellen Lukas
Roman Samulyak
No associations
LandOfFree
Stability and calibration of a water Cerenkov detector prototype does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Stability and calibration of a water Cerenkov detector prototype, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Stability and calibration of a water Cerenkov detector prototype will most certainly appreciate the feedback.