Fast signal shapes can be measured by using FADCs. Unfortunately, very fast FADCs are still quite expensive. Here we propose a multiplexing scheme which can allow one to measure signals from multiple channels by using a single FADC channel. One can apply the multiplexing in the experiments where a common event trigger exists and the trigger rate is not exceedingly high. We are considering to use the multiplexing principle for reading out the 600 ultrafast photomultiler (PMT) imaging camera of the 17 m MAGIC air Cherenkov telescope by using FADCs in the projects 2nd phase. The operation of the multiplexer is simple and is based on the use of fast linear switches which sequentially connect the signal channels, after appropriate delays, to the FADC input.