Physics
Scientific paper
May 2010
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2010jphcs.228a2039m&link_type=abstract
Journal of Physics: Conference Series, Volume 228, Issue 1, pp. 012039 (2010).
Physics
2
Scientific paper
The design of the Radiation Monitor in the LISA Technology Package on board LISA Pathfinder is based on two silicon PIN diodes, placed parallel to each other in a telescopic configuration. One of them will be able to record spectral information of the particle hitting the diode. A test campaign for the Flight Model Radiation Monitor is proposed to verify its performance. This paper shows the results obtained with a simulated flight model geometry using GEANT4, to be compared with the real data that will be obtained in a proton irradiation facility.
Diaz--Aguilo Marc
Grimani Catia
Lobo Alberto
Mateos Ignacio
Ramos-Castro Juan
No associations
LandOfFree
Proton irradiation test on the flight model radiation monitor for LISA Pathfinder does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Proton irradiation test on the flight model radiation monitor for LISA Pathfinder, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Proton irradiation test on the flight model radiation monitor for LISA Pathfinder will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-795144